MCRP 12-10B.1, page 317
Military Operations on Urbanized Terrain (MOUT)
Marine Corps Reference Publication: Military Operations on Urbanized Terrain (MOUT)
Public distribution statement A; S2 KOCOA cited as MCRP 12-10 b.1
Searchable page text (OCR / PDF)
Reinforced Concrete
Thickness of Material
TNT
C4
Size of Opening
Up to 10 cm
(4 inches)
.792 lbs
.591 lbs
10 to 15 cm
(4 to 6 inches)
10 to 20 cm
(4 to 8 inches)
3.4 lbs
2.54 lbs
15 to 30 cm
(6 to 12 inches)
Nonreinforced Concrete Masonry
Thickness of Material
TNT
C4
Size of Opening
Up to 35 cm
(14 inches)
3.66 lbs
2.73 lbs
35 cm
(14 inches)
35 to 45 cm
(14 to 18 inches)
7.5 lbs
5.6 lbs
45 cm
(18 inches)
45 to 50 cm
(18 to 20 inches)
10.2 lbs
7.61 lbs
50 cm
(20 inches)
Table F-2. Amounts of TNT and C4 Required To Breach Concrete
b. The engineers should furnish technical assistance for selective rubbling. Normally,
buildings can be rubbled by using shaped charges or C4 on the supports and major beams.
c.
Charges should be placed directly against the surface to be breached unless a shaped
charge is used. Whenever possible, demolitions should be tamped to increase their
effectiveness. Tamping materials could be sandbags, rubble, or desks and chairs (Figure F-12).
Figure F-12. Chair Used To Tamp Breaching Charge
Military Operations on Urbanized Terrain
F - 15